Rados Dosimeters








FEATURES
• small size and large display
• measurement in ¼ Sv/ h or mrem/ h
• gamma dose indication
• visual and audible signaling
• high battery life time ( > 1 year)
• compliant to IEC 60846
• dose rate follow-up by audible signal with frequency proportional to dose rate
• visual and audible alarm: user settable for dose and dose rate over the whole measurement range
• dose measurement
• histogram capability of up to 480 dose rate values with user settable logging interval
• backlit display with six large digits
• display in either ¼ Sv/ h or in mrem/ h built-in self diagnostics
Specification :
Radiological characteristics :
• radiation detected: gamma and X-ray from 48 keV to 1.3 MeV
• detector: energy compensated GM tube compliant to H* ( 10)
• dose rate measurement range: from 0.01 ¼ Sv/ h to 100 mSv/ h or from 1 ¼ rem/ h to 10 rem/ h
• dose rate linearity: ± 10 % ± 1 digit within the range of 0.1 ¼ Sv/ h to 100 mSv/ h or 10 ¼ rem/ h to 10 rem/ h
• calibration accuracy: ± 5 % of the reading in 137Cs exposure, at 3 mSv/ h, + 20° C ( 68° F)
• energy response: ± 30 % over the range of 48 keV - 1.3 MeV
• angular response: ± 25 % within ± 45 % from the calibration direction at 48 keV
• dose measurement range: from 0.01 ¼ Sv to 1 Sv or from 1 ¼ rem to 100 rem
Functional characteristics :
• dose rate follow-up by audible signal with frequency proportional to dose rate
• visual and audible alarm: user settable for dose and dose rate over the whole measurement range
• dose measurement ( ¼ Sv / mrem)
• histogram capability of up to 480 dose rate values with user settable logging interval
• backlit display with six large digits
• display in either ¼ Sv/ h or in mrem/ h ( configurable per request)
• built-in self diagnostics for GM-tube operation, high voltage and battery capacity
• Built-in infra-red port ( IrDA)
Mechanical characteristics :
• case: rugged plastic, easily decontaminable
• dimensions: 78 x 126 x 32 mm
• weight:
- 170 g without batteries
- 220 g with batteries
Envirionmental Characterstics :
• temperature range :
• – 25 ... + 55° C operational ( -13... 131° F)
– 40 ... + 70° C strorage ( -40... 158° F)
• protection level: IP67 ( temporary immersion / fl oating device)
Electrical characteristics :
• power supply: 2 alkaline batteries IEC LR6/ AA size ( recommended)
• battery life time: at least 2000 hours at normal background with alkaline cells ( more than 1 year under normal operation)
• battery alarm: two-step alarm for low battery voltage
• electromagnetic compatibility: CE compliant


ON SALE NOW!! Do you know if you are being exposed to harmful radiation? The RDX-2 affordable hand-held portable radiation meter is small enough to go anywhere and as sensitive as the $1000 professional models since RDX-2 Detects minuscule amounts of gamma, beta or X-rays. The units Geiger Muller tube Detects all gamma and beta isotopes released by nuclear power plants such as iodine and cesium. It is ideal for Homeland Security and for detecting environmental / industrial contamination. It can be used to screen for radiation in air, food and water. Designed for nontechnical persons the RDX-2 uses a very sensitive 200VDC, Geiger Muller tube detector; and yet offers easy one-button operation.
Included in this bundle is an RDX2 Meter + Bottle of RadBlock 200's
Radiation Alert Personal Pen Direct-Reading Dosimeter - W725, 0-5R with Sapphire Window
Model W725

Personal Pen Dosimeters Model W725
Direct-Reading Dosimeter - W725, 0-5R with Sapphire Window Model W725 0-5R
Direct-Reading Dosimeter with Sapphire Window
Model W725 Order (4349)
The Direct-Reading Dosimeter is pocket-size, carbon-fiber electroscope with an ion chamber for detecting and indication of integrated exposure to Gamma and X-Ray radiation. It has a thin wall which permits the penetration and detection of radiation. This model comes with a hardened sapphire window that won't scratch even in the toughest of conditions.
Dosimeters are extremely sensitive instruments. Although they are constructed for rugged use, they should receive the same care as a wristwatch. Since dosimeters are hermetically sealed at the factory, they cannot be repaired or adjusted in the field. Therefore, if instrument malfunctioning is experienced, the instrument should be returned to the factory or your dealer. Dosimeters may be maintained in operating condition simply by cleaning the eyepiece lens and the charging switch insulator with clean water and a cloth that is free of lint and grit. Make sure the charging switch insulator is absolutely free of lint and moisture at all times. Caution: Do not insert any sharp objects into, or tamper with parts in the charging switch recess. Irreparable damage may be done.
Arrow-Tech, Inc. recommends a yearly calibration of the Direct-Reading Dosimeter which is generally consistent with good health physics practices. More frequent calibration may be necessary should the user's license require a shorter calibration interval.
Licensed from the U.S. Government under Patent No. 5,426,305
Specifications:
Radiation Detected: Gamma and X-Ray from 16 keV to 6 MeV
Range: 0-5R
Detector: Fiber-Electrometer mounted in an Electrically Conductive Plastic Ion Chamber
Detector Housing: Very low permeability plastics - Hermetically-Sealed
Accuracy: +/– 10% of true exposure
Rate Response: Dose rate independent for Gamma and X-Ray
Electrical Leakage: Less than 1.0% of full scale for 24 hours at 50 C
Temperature Range: -20 degrees C to +50 degrees C
Relative Humidity: Up to 90%
Dimensions: 4.5” (12.4 cm) Length X .6“ (1.5 cm) Diameter
Weight: 1.0 oz. (25 grams)
Finish: Natural Matte Gray with a Metal Clip
Warranty: Two Year Limited Warranty
Shelf Life: 20 Years
Specifications: ANSI N13.5 and ANSI N322-1997
DMC 3000 Electronic Personal Dosimeter

The DMC 3000 - Personal Electronic Dosimeter - X-ray & Gamma
The DMC 3000 covers a wide range of X-Ray and Gamma radiation detection field from 15keV to 7Mev and linear response to dose rate fields from natural background up to more than 10 Sv/h. The pass-by data exchange feature gives unequal operational flexibility. In-motion reading allows dose management by sub-zone as well as real-time location tracking of personnel.
FEATURES
- Loud alarm, 85 dB (A) typical, (> 90 dB (C) peak)
- Vibrating alarm
- Highly visible backlit display
- Optional beta, neutron or telemetry module
- Factory upgradeable firmware
- Simple 2-button navigation
- Extended dose rate alarms
- Dual ultrabright LED alarm
- Superior X-ray and gamma energy response
- Meets or exceeds applicable IEC and ANSI standards
- Designed for ruggedness and durability
TECHNICAL SPECIFICATIONS:
Radiological Characteristics
- Compliant with IEC 61526Ed. 3, ANSI 42.20(*) (*) isotropy 241Am and 137Cs with ± 75° angle Measurement and display
- Energy response better than ± 20% (typically ± 10%)
- Accuracy Hp(10): ≤ ± 10%* (137Cs, ~ 24 mSv/h); ≤ ± 15%*, (241Am, ~ 23 mSv/h); ≤ ± 19%** X-ray 16keV (*including ± 5% extended uncertainty k=2); (** including ± 9% extended uncertainty k=2)
- Display dose: 1 µSv to 10 Sv (0.1 mrem to 1000 rem)
- Display rate: 10 µSv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) or 1 µSv/h to 10 Sv/h (0.1 mrem/h to 1000 rem/h) extended option.
- Dose Rate Linearity: < ± 20% up to 10 Sv/h (1000 rem/h) (Co and X H30 20 keV); < ± 20% up to 6 Sv/h (600 rem/h) (Pulsed X-rays 20 ms width, 1, 10 & 20 pps)
Electrical Characteristics
- Standard AAA (LR03) 1.5 V Alkaline battery
9 calendar month battery life (typical, 8 h per day,
5 days per week in run mode, without excessive alarms)*
- 2500 h battery life in continuous run, without excessive alarm
Mechanical Characteristics
- Rugged, high impact polycarbonate-ABS case
- Dimensions: 86 x 56 x 21 mm (3.4 x 2.2 x 0.8 in) without clip
- Weight with alkaline battery and clip: < 88 g (3.1 oz)
- Worn by a replaceable clips (2 different style back clips or one a front-facing clip for DMC worn inside the pocket)
Environmental Characteristics
- Temperature range: -10°C to 50°C (14°F to 122°F): deviation in response less than ± 5%
- Relative humidity: < 90% at 42°C (108°F)
- Storage: -20°C to 71°C (-4°F to 160°F)
- Shock, vibration and drop resistant (1.5 meter on concrete)
- Waterproof IP67: 1m (39 in) during 1 hour
- EMC: complies and exceeds standards by a large margin ( compliant, certificate number: 153720)
- MIL STD 461F RS103 (pulsed electric field): exceeds 200 V/m from 30 kHz to 5 GHz
- MIL STD 461F RS101 (magnetic field 30 Hz - 100 kHz)
- Factory calibration approved under ISO/IEC 17025, COFRAC accreditation Nber 2-1663

The Ranger is a small, handheld, microprocessor-based instrument which offers excellent sensitivity to low levels of alpha, beta, gamma, and
x-rays and has built in efficiencies for common isotopes to calculate activity in Bq and DPM. It has a backlit digital display, a red count light, and a beeper that sounds with each count detected.
Other features include selectable alert levels, an adjustable timer, and an optional wipe test plate for swipes. Internal memory and the free Observer USB Software that allows you to download your data, set computer alarms, and calibrate your instrument!

Specifications
Detector
Operating RangemR/hr – .001 (1µR) to 100 CPM – 0 to 350,000 µSv/hr – .01 to 1000 CPS – 0 to 5000 Total Counts- 1 to 9,999,000 counts |
Energy Sensitivity
Detects Alpha down to 2 MeV. Detects Beta down to .16 MeV; typical detection efficiency at 1 MeV is approx. 25%. Detects Gamma down to 10 KeV through the detector window. 3340 CPM/mR/hr (137Cs). Smallest detectable level for 125I is .02 µCi at contact.
Built-in Efficiencies
Sulfur (35S), Strontium (90Sr/y), Cesium (137Cs), Phosphorus (32P), Carbon (14C), Iodine (131I), Cobalt (60Co), and Alpha
Display
Graphic LCD with Backlight
Anti Saturation
Meter will hold at OVER RANGE in fields as high as 100 times the maximum reading.
Averaging Periods
This radiation detector display updates every 3 seconds. At low background levels, the update is the average for the past 30-second time period. The timed period for the average decreases as the radiation level increases
Outputs
USB for use with Free Observer USB Software for PCs
Bluetooth for use with the Free Observer BLE App for Android.
Count Light
Red LED flashes with each radiation event.
Audio Indicator
Internally mounted beeper (can be switched off for silent operation)
Power Requirements
USB Power or Two (2) AA alkaline batteries (included). Approx. 800 hrs @ background.
Accuracy
Reference to Cs137
Typically ±15% from factory, ±10% with NIST Source Calibration NIST Calibration Additional
Selectable Alert Settings
mR/hr .001 – 100 and CPM 1 – 350,000. Pulsating beeper sounds the alert. Adjustable alert levels are used for mR/hr / CPM, and µSv/hr / CPS. 70db @ 1m. Alarm will sound when in Timer Mode when set alarm threshold is reached.
Temperature Range
-10° to +50°C (14° to 122°F)
Humidity
10% to 70% Non-Condensing.
Size
140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.)
Weight
291g (0.64 lbs.)
Includes
Carrying Case, Xtreme Boot, Lanyard, Stand, Batteries, Mini-USB Cable, Observer USB Software, Observer BLE Software, Certificate of Conformance
Options
Wipe Test Plate, Swipes, Water Resistance Case, NIST Calibration
Limited Warranty
1 year limited warranty
Radiation Alert Personal Pen Dosimeters Model W138

Personal Pen Dosimeters Model W138
- Rugged charger requires no batteries — simply squeeze the trigger of this piezoelectric generator to move the hairline fiber inside the dosimeter back to zero
- Clamping mechanism automatically locks the dosimeter in place
- Charger is easy to operate and requires only few squeezes of the trigger for each dosimeter
Direct-Reading Dosimeter with Sapphire Window
Model W138 (Order 4329)
The Direct-Reading Dosimeter is a pocket-size, carbon-fiber electroscope with an ion chamber for detecting and indication of integrated exposure to Gamma and X-Ray radiation. It has a thin wall which permits the penetration and detection of radiation. This model comes with a hardened sapphire window that won't scratch even in the toughest of conditions.
Dosimeters are extremely sensitive instruments. Although they are constructed for rugged use, they should receive the same care as a wristwatch. Since dosimeters are hermetically sealed at the factory, they cannot be repaired or adjusted in the field. Therefore, if instrument malfunctioning is experienced, the instrument should be returned to the factory or your dealer. Dosimeters may be maintained in operating condition simply by cleaning the eyepiece lens and the charging switch insulator with clean water and a cloth that is free of lint and grit. Make sure the charging switch insulator is absolutely free of lint and moisture at all times. Caution: Do not insert any sharp objects into, or tamper with parts in the charging switch recess. Irreparable damage may be done.
Arrow-Tech, Inc. recommends a yearly calibration of the Direct-Reading Dosimeter which is generally consistent with good health physics practices. More frequent calibration may be necessary should the user's license require a shorter calibration interval.
Licensed from the U.S. Government under Patent No. 5,426,305
Specifications:
Radiation Detected: Gamma and X-Ray from 16 keV to 6 MeV
Range: 0-200mR
Detector: Fiber-Electrometer mounted in an Electrically Conductive Plastic Ion Chamber
Detector Housing: Very low permeability plastics - Hermetically-Sealed
Accuracy: +/– 10% of true exposure
Rate Response: Dose rate independent for Gamma and X-Ray
Electrical Leakage: Less than 1.0% of full scale for 24 hours at 50 C
Temperature Range: -20 degrees C to +50 degrees C
Relative Humidity: Up to 90%
Dimensions: 4.5” (12.4 cm) Length X .6“ (1.5 cm) Diameter
Weight: 1.0 oz. (25 grams)
Finish: Natural Matte Gray with a Metal Clip
Warranty: Two Year Limited Warranty
Shelf Life: 20 Years
Specifications: ANSI N13.5 and ANSI N322-1997



ON SALE NOW!! Do you know if you are being exposed to harmful radiation? The RDX-2 affordable hand-held portable radiation meter is small enough to go anywhere and as sensitive as the $1000 professional models since RDX-2 Detects minuscule amounts of gamma, beta or X-rays. The units Geiger Muller tube Detects all gamma and beta isotopes released by nuclear power plants such as iodine and cesium. It is ideal for Homeland Security and for detecting environmental / industrial contamination. It can be used to screen for radiation in air, food and water. Designed for nontechnical persons the RDX-2 uses a very sensitive 200VDC, Geiger Muller tube detector; and yet offers easy one-button operation.
- 1